Station name: Aragats Neutron Monitor (Արագած)
Station short name: ARNM
Start date: 2000-04-01
End date: None
Head organization: Cosmic Ray Division (CRD) of A.I. Alikhanyan National Science Laboratory, 2 Alikhanyan Brothers St.,Yerevan 0036, Armenia
Principal investigator: Information withheld according to EU GDPR, please contact us at questions@nmdb.eu
Contact person: Information withheld according to EU GDPR, please contact us at questions@nmdb.eu
Latitude [°]: 40.47
Longitude [°]: 44.18
Altitude [m] asl: 3200.0
Geomagnetic cutoff rigidity [GV]: 7.1
Average count rate [s-1] during solar activity minimum: 690.0
Average count rate [s-1] during solar activity maximum: 590.0
Reference atmospheric pressure [mbar]: 690.0
Barometric coefficient [%/mbar]: 0.688
Information on detector housing: Roof construction: metallic tilt,  wood, 8 g/cm^2
Type of counter tube: CHM-15, transimpedance preamplifier. Dead time of preamp: ~400ns
Number of counter tubes: 18
Information on detector: Moderator: Polyethylene, Reflector: Polyethylene, 3 sections X 6 counters
Atmospheric pressure sensor: 1.5% max. error, 0 to 85 C, sensitivity: 45mV/kPa, temperature compensated -40 to 125 C
Information about clock: NTP server sincroniced by GPS